How to reduce the harm in laparoscopic surgery

First, before the epidemic, many literatures reported that the aerosol produced by the smoke in the operating room contained many harmful components, which had certain adverse effects on the health of medical workers. In the epidemic period, the control of aerosol in the operating room is particularly important. The SAGES and EAES report highlights the following considerations for avoiding aerosol production during surgery:

1. Improve the awareness of protection: awareness determines behavior, and improving the awareness and prevention awareness of medical staff in the operating room is the primary condition.

2. The incision of laparoscopic surgery should be as small as possible to ensure the passage of trocar and avoid the phenomenon of air leakage caused by gaps; Maintain low and adequate pneumoperitoneum pressure levels; It is recommended to consider the laparoscopic gas smoke filtration and emission system.

3. Choose appropriate personal protection measures: Wear surgical masks correctly, but because the minimum filter particles of surgical masks are 5um, they cannot completely block smaller chemical particles or viral particles in surgical smoke, so they cannot be completely relied on.

4. Establish a good discharge system in the operating room.

5. Correct use of surgical electrical equipment.

6. Good attraction system.

Two: In order to ensure the health and safety of medical personnel and patients, the effective protective measure is to set up reasonable smoke extraction facilities and prevent smoke inhalation.

1. Surgical smoke consists of 95% water or steam and 5% cell fragments in the form of particles. Particles contain harmful chemicals, biological particles, active cellular material or viruses, inactive particles, carbonized tissues, and bacteria.

2. Electrosurgical equipment can produce particles as small as 0.1μm, laser equipment can produce particles with an average diameter of 0.3μm, and ultrasonic knives will produce particles with an average diameter of 0.35μm~6.5μm. These tiny particles are inhaled by the human body, and then deposited directly in the alveoli, damaging human health.

3. Smoke produced by energy instruments used in surgery contains more than 600 kinds of organic compounds, most of which will cause certain harm to human health. Long-term inhalation or exposure to these contaminants can induce diseases of the respiratory, digestive, reproductive, nervous, blood, and immune systems.

There may also be virus particles, cell active fragments, DNA fragments and other biologically active substances in surgical smoke. For example, studies have found that surgical smoke contains complete DNA fragments of bovine fibropapillomavirus (BPV) and human papillomavirus (HPV), while human immunodeficiency virus (HIV), human papillomavirus (HPV), human immunodeficiency virus (HIV) and human papillomavirus (HPV). Figure 1-2) can remain active in the smoke produced by the CO2 laser for 14 days and disappear completely after 28 days. In 1992, GattiBryant et al. collected smoke generated during breast plastic surgery and found that it induced mutations in Salmonella TA98 strain. At present, the number of HIV infections in China is more than 800,000, and the hepatitis B virus (HBV) infection rate of the population is more than 10%, which greatly increases the potential risk of HIV, HBV, HPV and other viruses.

Three: Smoke extraction system should be set up to immediately eliminate surgical smoke, and personal protective measures should be taken:

1. Application of central smoke exhaust system:

(1) In the operating room should be equipped with a high efficiency filtration system of surgical smoke extraction equipment, the exhaust rate must reach 30 to 45 meters/minute.

(2) In order to effectively prevent hospital infection, the central smoke exhaust system needs to use a micro-particle filter with more than 99% efficiency.

(3) The operating room can choose to install a fresh air system with physical mechanical ventilation and purification function, mobile air filtration purification smoke exhaust device and other methods to purify the air in the operating room.

2. Application of mobile smoke exhaust system:

(1) Smoke evacuation equipment will not interfere with the surgical activities of the surgeon;

(2) It has a large enough negative pressure attraction to ensure effective smoke removal;

(3) There is enough filtration capacity to ensure the safety of the ambient air filtration system, of which the filtration system is particularly heaviest, it must be able to accommodate all the smoke generated, effectively remove harmful ingredients and odor, easy to operate.

3. Personal protection requirements

(1) Pay attention to the protection of breathing, it is recommended to wear a high performance filter surgical mask, gloves and wear isolation clothes, which should be able to effectively filter particles of 0.01μm diameter.

(2) Because surgical smoke may be adsorbed on the surface, studies have shown that contact lenses will adsorb more surgical smoke, so it is recommended to wear surgical protective glasses during surgery.