BFS (Blow Fill Seal) technology originated in Germany and has been widely used in the 1960s. At first it was mainly used in products such as rinses. In the 1970s, it was used in small-volume injections (such as eye drops packaging) and in the 1980s. For large-volume injections (such as infusion bottles). It is now widely used in the fields of plastic packaging terminal sterilization products, aseptic products, especially in pharmaceutical packagings, like LVP using PP caps, Euro head caps, PP ports, etc., and is suitable for mass, uninterrupted production of products.
BFS process starts by extruding a sterile polymer tube directly into the system. The container is then immediately formed, filled, sealed and demolded. Integrated operation, closed system, without external intervention. The delicate logistics of prefabricated containers and the time-consuming cleaning and sterilization process are no longer required.
The entire filling path including the batching system is specially designed for CIP/SIP. This means that all product transportation lines are cleaned through an automated procedure, sterilized with compressed steam and dried with sterile filtered air. This makes BFS technology the safest aseptic filling method.
The plastic tube extruded from the granules is fed into the opened blow mold
The main mold is closed to seal the bottom of the container. The mandrel enters the neck of the mold, and compressed air is used to blow the tube blank into shape. Smaller containers are vacuum formed.
The liquid medicine is filled into the container through the mandrel under the precise control of the filling system.
The mandrel is removed, the head mold is closed, and the designed sealing part is vacuum formed.
Open the mold, the container leaves the mold, and the next cycle begins. The conveyor belt takes the container to the next process.
Whether it is to fill a bottle or an ampoule, what to fill, how to fill it, and what function the container needs are usually based on the end uasge. The BFS equipment can use different plastics to automatically produce different containers such as cans, tubes, ampoules, dropper bottles, pouch bottles and single-dose packaging. The filling volume ranges from 0.04 to 10,000 ml.
BFS technology can be used for aseptic packaging of ophthalmic products, respiratory (inhalation) drugs, biological preparations, vaccines and other injection drugs, enabling continuous, automatic molding, filling and sealing of unit-dose liquid packaging.
Avaliable packaging containers include ampoules, vials and bottles, and the sterility of the product can be guaranteed during the entire process. Compared with glass packaging, the benefits of BFS include reducing waste and breakage, and eliminating product preservatives that may be allergic to patients.
Fully enclosed to effectively isolate particles: It has a closed system that is isolated from the outside world, and the liquid medicine transmission system, filtration system, and filling system are fully enclosed, which can effectively control and isolate particles.
Integrated and more efficient: Blow molding, filling, and sealing are completed in the same station of the same equipment, forming in one step, and the whole process takes only 11 seconds.
High performance, sterile and dust-free: automatic online cleaning/sterilization, the system maintains a positive pressure, which can achieve sterile effects.
Process of Aseptic Blow-Fill-Seal Technology
Extrusion
Forming
Filling
Sealing
Demold
Application of Blow Fill Seal Equipment
Technical Advantages of BFS